Patented digital surgical stent & Keystone Prima implant
Sex: Female Age: 42 years
Health condition : good
C.C. : Upper Right tooth accidentally biting pain
D.D. : Upper Right the first molar accidentally biting fracture
Treatment Plan:
1.Extraction
2.Socket preservation
3.Implant setting i sinus lift
4.Crown restoration
Upper Right the first molar
Digital Panograph Film



Extraction

Socket preservation ( FDBA + Collagen )




Treatment Plan:
1. Bone height 6.64 mm
2. Osteotome using
3. 4.1 mm x 10 mm Prima

Invention Patented digital surgical stent
2.3mm & 3.6mm


3 months later ; after socket preservation

Invention Patented digital surgical stent

Bone Height: 6.64 mm

lingual bony defect

Osteotome

- Drill 2.0 mm – to 4 mm
- Straight 2.0 (convex)- to 9 mm
- 2.0 mm-2.8 mm – to 10 mm
- 2.8 mm-3.3 mm – to 10 mm
- 3.4 mm-3.8 mm – to 10 mm
.4.1 mm x 10 mm Prima
Guide Pin


collagen membrane




Implant planning & prosthetic evaluation





prima - 4.1 mm x 10 mm (15617K) bone level 0.5 mm






impression copping


Screw Type Crown setting under 35 Nt-cm



soft tissue molding emergence profile

Prima
4.1 mm x 10 mm (15617K) bone level 0.5 mm

Before and After

4 months after crown setting




DEAN MEI HUA LEE
- TAOi President DDS ( 2018~2020 )
- Present Dental implant specialist of TAOi
- Academy of Osseointegration International Affiliate Member ( 2019/09 )
- Taiwan Alliance of Dental Implant Association Diplomate ( 2019/12 ~2025/12 )
The invention patent owner 3D implant surgical stent ( USA , Taiwan , China )
Implant Certification of Michigan / Toronto U. ( 2007/08 , 2010/08 )
- Assistant professor of Michigan University USA ( 2018/07 )
- ICOI XXIV World Congress & 10th AP–Section Congress of International Congress of Oral Implantologists ( 2006/10 )
- Fellow ICOI